Summary: Initramfs generator using udev
Summary(pl.UTF-8): Generator initramfs wykorzystujÄ…cy udev
Name: dracut
-Version: 030
+Version: 032
Release: 1
License: GPL v2+
Group: Base
Source0: http://ftp.kernel.org/pub/linux/utils/boot/dracut/%{name}-%{version}.tar.xz
-# Source0-md5: 541c7f861b7fe64ae6114e546d75af4f
+# Source0-md5: 3e74a9429ea22bf4e92bf59c4ccdfe75
Source1: pld.conf
Patch0: bash-sh.patch
Patch1: plymouth-libexec.patch
%attr(755,root,root) %{dracutlibdir}/dracut-functions
%attr(755,root,root) %{dracutlibdir}/dracut-logger.sh
%attr(755,root,root) %{dracutlibdir}/dracut-initramfs-restore
+%dir %{dracutlibdir}/modules.d/00bash
+%attr(755,root,root) %{dracutlibdir}/modules.d/00bash/module-setup.sh
%dir %{dracutlibdir}/modules.d/00bootchart
%attr(755,root,root) %{dracutlibdir}/modules.d/00bootchart/*.sh
%dir %{dracutlibdir}/modules.d/00dash
%attr(755,root,root) %{dracutlibdir}/modules.d/00systemd-bootchart/*.sh
%dir %{dracutlibdir}/modules.d/01bash
%attr(755,root,root) %{dracutlibdir}/modules.d/01bash/*.sh
+%dir %{dracutlibdir}/modules.d/03modsign
+%attr(755,root,root) %{dracutlibdir}/modules.d/03modsign/*.sh
%dir %{dracutlibdir}/modules.d/03rescue
%attr(755,root,root) %{dracutlibdir}/modules.d/03rescue/module-setup.sh
%dir %{dracutlibdir}/modules.d/04watchdog
%attr(755,root,root) %{dracutlibdir}/modules.d/50plymouth/*.sh
%dir %{dracutlibdir}/modules.d/80cms
%attr(755,root,root) %{dracutlibdir}/modules.d/80cms/*.sh
+%dir %{dracutlibdir}/modules.d/90bcache
+%attr(755,root,root) %{dracutlibdir}/modules.d/90bcache/module-setup.sh
%dir %{dracutlibdir}/modules.d/90btrfs
%{dracutlibdir}/modules.d/90btrfs/*.rules
%attr(755,root,root) %{dracutlibdir}/modules.d/90btrfs/*.sh
---- dracut-020/modules.d/50plymouth/plymouth-populate-initrd.sh~ 2012-08-09 13:49:07.894845601 +0200
-+++ dracut-020/modules.d/50plymouth/plymouth-populate-initrd.sh 2012-08-09 13:50:43.211508906 +0200
-@@ -6,9 +6,10 @@
+--- dracut-032/modules.d/50plymouth/plymouth-populate-initrd.sh.orig 2013-08-26 21:31:12.615640993 +0200
++++ dracut-032/modules.d/50plymouth/plymouth-populate-initrd.sh 2013-08-27 15:35:36.416243854 +0200
+@@ -5,9 +5,10 @@
PLYMOUTH_THEME=$(plymouth-set-default-theme)
- dracut_install plymouthd plymouth \
+ inst_multiple plymouthd plymouth \
- "${PLYMOUTH_LOGO_FILE}" \
/etc/os-release
-+[[ -f "${PLYMOUTH_LOGO_FILE}" ]] && dracut_install "${PLYMOUTH_LOGO_FILE}"
++[[ -f "${PLYMOUTH_LOGO_FILE}" ]] && inst_multiple "${PLYMOUTH_LOGO_FILE}"
+
mkdir -m 0755 -p "${initdir}/usr/share/plymouth"
---- dracut-029/dracut.sh~ 2013-06-14 15:31:28.000000000 +0200
-+++ dracut-029/dracut.sh 2013-06-19 08:29:40.828089414 +0200
-@@ -1148,10 +1148,10 @@
+--- dracut-032/dracut.sh.orig 2013-08-27 15:36:03.692909358 +0200
++++ dracut-032/dracut.sh 2013-08-27 15:39:08.759568281 +0200
+@@ -1234,10 +1234,10 @@
if [[ $UID = 0 ]] && [[ $PRELINK_BIN ]]; then
if [[ $DRACUT_FIPS_MODE ]]; then
dinfo "*** Installing prelink files ***"
-- dracut_install -o prelink /etc/prelink.conf /etc/prelink.conf.d/*.conf /etc/prelink.cache
-+ dracut_install -l -o prelink /etc/prelink.conf /etc/prelink.conf.d/*.conf /etc/prelink.cache
+- inst_multiple -o prelink /etc/prelink.conf /etc/prelink.conf.d/*.conf /etc/prelink.cache
++ inst_multiple -l -o prelink /etc/prelink.conf /etc/prelink.conf.d/*.conf /etc/prelink.cache
else
dinfo "*** Pre-linking files ***"
-- dracut_install -o prelink /etc/prelink.conf /etc/prelink.conf.d/*.conf
-+ dracut_install -l -o prelink /etc/prelink.conf /etc/prelink.conf.d/*.conf
+- inst_multiple -o prelink /etc/prelink.conf /etc/prelink.conf.d/*.conf
++ inst_multiple -l -o prelink /etc/prelink.conf /etc/prelink.conf.d/*.conf
chroot "$initdir" "$PRELINK_BIN" -a
- rm -f "$initdir/$PRELINK_BIN"
- rm -fr "$initdir"/etc/prelink.*
+ rm -f -- "$initdir/$PRELINK_BIN"
+ rm -fr -- "$initdir"/etc/prelink.*