]>
Commit | Line | Data |
---|---|---|
bc935a7a JR |
1 | #!/bin/sh |
2 | # | |
3 | # ganeti-confd Start/Stop Ganeti Cluster config daemon. | |
4 | # | |
5 | # chkconfig: 2345 99 01 | |
6 | # description: Ganeti Cluster config daemon. | |
7 | # | |
8 | # processname: ganeti-confd | |
9 | # pidfile: /var/run/ganeti/ganeti-confd.pid | |
10 | # | |
11 | ### BEGIN INIT INFO | |
12 | # Provides: ganeti-confd | |
13 | # Required-Start: $syslog $remote_fs | |
14 | # Required-Stop: $syslog $remote_fs | |
15 | # Default-Start: 2 3 4 5 | |
16 | # Default-Stop: 0 1 6 | |
17 | # Short-Description: Ganeti Cluster config daemon | |
18 | # Description: Ganeti Cluster config daemon | |
19 | ### END INIT INFO | |
20 | ||
21 | # Source function library. | |
22 | . /etc/rc.d/init.d/functions | |
23 | ||
24 | # Get service config | |
25 | [ -f /etc/sysconfig/ganeti ] && . /etc/sysconfig/ganeti | |
26 | ||
27 | if [ ! -f /var/lib/ganeti/server.pem ]; then | |
28 | echo "Missing configuration file /var/lib/ganeti/server.pem" | |
29 | exit 1 | |
30 | fi | |
31 | ||
32 | start() { | |
33 | # Check if the service is already running? | |
34 | if [ -f /var/lock/subsys/ganeti-confd ]; then | |
35 | msg_already_running "Ganeti Cluster config daemon" | |
36 | return | |
37 | fi | |
38 | ||
39 | msg_starting "Ganeti Cluster config daemon" | |
40 | daemon --user USER --pidfile /var/run/ganeti/ganeti-confd.pid /usr/sbin/ganeti-confd $CONFD_ARGS | |
41 | RETVAL=$? | |
42 | [ $RETVAL -eq 0 ] && touch /var/lock/subsys/ganeti-confd | |
43 | } | |
44 | ||
45 | stop() { | |
46 | if [ ! -f /var/lock/subsys/ganeti-confd ]; then | |
47 | msg_not_running "Ganeti Cluster config daemon" | |
48 | return | |
49 | fi | |
50 | ||
51 | msg_stopping "Ganeti Cluster daemon" | |
52 | killproc --pidfile /var/run/ganeti/ganeti-confd.pid ganeti-confd | |
53 | rm -f /var/lock/subsys/ganeti-confd | |
54 | } | |
55 | ||
56 | # HUP causes daemon to reopen logs only | |
57 | reload() { | |
58 | if [ ! -f /var/lock/subsys/ganeti-confd ]; then | |
59 | msg_not_running "Ganeti Cluster config daemon" | |
60 | RETVAL=7 | |
61 | return | |
62 | fi | |
63 | ||
64 | msg_reloading "Ganeti Cluster config daemon" | |
65 | killproc ganeti-confd -HUP | |
66 | RETVAL=$? | |
67 | } | |
68 | ||
69 | condrestart() { | |
70 | if [ ! -f /var/lock/subsys/ganeti-confd ]; then | |
71 | msg_not_running "Ganeti Cluster config daemon" | |
72 | RETVAL=$1 | |
73 | return | |
74 | fi | |
75 | ||
76 | stop | |
77 | start | |
78 | } | |
79 | ||
80 | RETVAL=0 | |
81 | # See how we were called. | |
82 | case "$1" in | |
83 | start) | |
84 | start | |
85 | ;; | |
86 | stop) | |
87 | stop | |
88 | ;; | |
89 | restart) | |
90 | stop | |
91 | start | |
92 | ;; | |
93 | try-restart) | |
94 | condrestart 0 | |
95 | ;; | |
96 | reload|force-reload|flush-logs) | |
97 | reload | |
98 | ;; | |
99 | status) | |
100 | status --pidfile /var/run/ganeti/ganeti-confd.pid ganeti-confd | |
101 | exit $? | |
102 | ;; | |
103 | *) | |
104 | msg_usage "$0 {start|stop|restart|try-restart|reload|force-reload|flush-logs|status}" | |
105 | exit 3 | |
106 | esac | |
107 | ||
108 | exit $RETVAL |