X-Git-Url: http://git.pld-linux.org/?p=packages%2Fganeti.git;a=blobdiff_plain;f=ganeti.spec;h=d4db87eebef7db65b1629cc987dbe42072bd8df1;hp=dc9bac643bcfc0787d6b2310d0d0505b24e867c2;hb=8476307eea0e3ac9bb3712970731f0491d4ab2ae;hpb=612be331eaf42d132ccf97de54704e0c4fbe990c;ds=sidebyside diff --git a/ganeti.spec b/ganeti.spec index dc9bac6..d4db87e 100644 --- a/ganeti.spec +++ b/ganeti.spec @@ -1,11 +1,11 @@ Summary: Cluster-based virtualization management software Name: ganeti -Version: 2.8.1 -Release: 0.4 +Version: 2.9.3 +Release: 0.9 License: GPL v2 Group: Applications/System -Source0: https://ganeti.googlecode.com/files/%{name}-%{version}.tar.gz -# Source0-md5: ade147740c2f630e0cdbb14a70e9c3ef +Source0: http://downloads.ganeti.org/releases/2.9/%{name}-%{version}.tar.gz +# Source0-md5: 0542ca872bf2d57284359fcc8dc565ef Source1: %{name}.tmpfiles Source2: %{name}-confd.init Source3: %{name}-masterd.init @@ -17,6 +17,8 @@ Source8: %{name}.sysconfig Patch0: fix-no-kvm.patch Patch1: systemd.patch Patch2: daemon-util-use-service.patch +Patch3: mtl.patch +Patch4: use-vm-openvswitch-link.patch URL: https://code.google.com/p/ganeti/ BuildRequires: autoconf BuildRequires: automake @@ -31,20 +33,25 @@ BuildRequires: ghc-haskell-platform BuildRequires: ghc-hinotify BuildRequires: ghc-hslogger >= 1.2.3 BuildRequires: ghc-json -BuildRequires: ghc-snap-server BuildRequires: ghc-regex-pcre +BuildRequires: ghc-snap-server +BuildRequires: ghc-temporary BuildRequires: ghc-utf8-string BuildRequires: gmp-devel BuildRequires: hlint BuildRequires: hscolour +BuildRequires: pandoc BuildRequires: python BuildRequires: python-affinity BuildRequires: python-bitarray +BuildRequires: python-coverage BuildRequires: python-devel BuildRequires: python-distribute BuildRequires: python-ipaddr +BuildRequires: python-mock >= 1.0.1 BuildRequires: python-modules BuildRequires: python-paramiko +BuildRequires: python-pep8 BuildRequires: python-pyOpenSSL BuildRequires: python-pycurl BuildRequires: python-pyinotify @@ -56,7 +63,6 @@ Requires(post,preun): /sbin/chkconfig Requires(post,preun,postun): systemd-units >= 38 Requires: bridge-utils Requires: drbdsetup >= 8.0.12 -Requires: drbd-udev Requires: iproute2 Requires: iputils-arping Requires: lvm2 @@ -77,9 +83,10 @@ Requires: python-pyparsing Requires: python-simplejson Requires: rc-scripts Requires: socat +Requires: sudo Requires: systemd-units >= 0.38 #Suggests: ganeti-instance-debootstrap -Suggests: qemu-kvm +Suggests: qemu Suggests: xen BuildRoot: %{tmpdir}/%{name}-%{version}-root-%(id -u -n) @@ -116,6 +123,8 @@ bash-completion for ganeti. %patch0 -p1 %patch1 -p1 %patch2 -p1 +%patch3 -p1 +%patch4 -p1 %build %{__aclocal} -I autotools @@ -125,29 +134,36 @@ bash-completion for ganeti. %configure \ IP_PATH=/sbin/ip \ DOT=/usr/bin/dot \ + PYCOVERAGE=/usr/bin/coverage-%{py_ver} \ PYLINT=/usr/bin/pylint \ SOCAT=/usr/bin/socat \ QEMUIMG_PATH=/usr/bin/qemu-img \ --enable-syslog \ - --enable-htools-rapi \ - --enable-confd=python \ + --enable-confd \ + --enable-monitoring \ --enable-socat-escape \ --with-ssh-initscript=/etc/rc.d/init.d/sshd \ --with-ssh-config-dir=/etc/ssh \ - --with-xen-cmd=xl \ - --with-kvm-path=/usr/bin/qemu-kvm + --with-kvm-path=/usr/bin/qemu-kvm \ + --enable-restricted-commands \ + --with-user-prefix="gnt-" \ + --with-group-prefix="gnt-" \ + --with-export-dir=/var/lib/ganeti/export \ + --with-iallocator-search-path=%{_libdir}/ganeti/iallocators \ + --with-os-search-path=/srv/ganeti/os,%{_libdir}/ganeti/os,%{_datadir}/ganeti/os \ + --with-extstorage-search-path=/srv/ganeti/extstorage,%{_libdir}/ganeti/extstorage,%{_datadir}/ganeti/extstorage %{__make} %install rm -rf $RPM_BUILD_ROOT install -d $RPM_BUILD_ROOT{%{systemdunitdir},%{systemdtmpfilesdir}} \ - $RPM_BUILD_ROOT/etc/{ganeti,cron.d,bash_completion.d,sysconfig,rc.d/init.d} + $RPM_BUILD_ROOT/etc/{ganeti,cron.d,bash_completion.d,sysconfig,rc.d/init.d,sudoers.d,logrotate.d} %{__make} install \ DESTDIR=$RPM_BUILD_ROOT -install -d $RPM_BUILD_ROOT%{_datadir}/ganeti/os +install -d $RPM_BUILD_ROOT{%{_libdir},%{_datadir}}/ganeti/{os,extstorage} cp -p %{SOURCE1} $RPM_BUILD_ROOT%{systemdtmpfilesdir}/ganeti.conf install -p %{SOURCE2} $RPM_BUILD_ROOT/etc/rc.d/init.d/ganeti-confd @@ -164,14 +180,28 @@ cp -p %{SOURCE8} $RPM_BUILD_ROOT/etc/sysconfig/ganeti cp -p doc/examples/bash_completion $RPM_BUILD_ROOT/etc/bash_completion.d/ganeti cp -p doc/examples/ganeti.cron $RPM_BUILD_ROOT/etc/cron.d/ganeti cp -p doc/examples/ganeti.target $RPM_BUILD_ROOT%{systemdunitdir} -cp -p doc/examples/ganeti.target $RPM_BUILD_ROOT%{systemdunitdir} cp -p doc/examples/ganeti-{noded,masterd,rapi,confd,luxid,mond}.service $RPM_BUILD_ROOT%{systemdunitdir} +cp -p doc/examples/ganeti.sudoers $RPM_BUILD_ROOT/etc/sudoers.d/ganeti +cp -p doc/examples/ganeti.logrotate $RPM_BUILD_ROOT/etc/logrotate.d/ganeti +cp -p doc/examples/gnt-config-backup $RPM_BUILD_ROOT%{_sbindir} %py_postclean %clean rm -rf $RPM_BUILD_ROOT +%pre +%groupadd -g 300 gnt-masterd +%groupadd -g 301 gnt-confd +%groupadd -g 302 gnt-luxid +%groupadd -g 303 gnt-rapi +%groupadd -g 304 gnt-daemons +%groupadd -g 305 gnt-admin +%useradd -u 300 -d /var/lib/ganeti -g gnt-masterd -G gnt-daemons,gnt-confd,gnt-admin -c "Ganeti Masterd User" gnt-masterd +%useradd -u 301 -d /var/lib/ganeti -g gnt-confd -G gnt-daemons -c "Ganeti Confd User" gnt-confd +%useradd -u 302 -d /var/lib/ganeti -g gnt-luxid -G gnt-daemons,gnt-confd,gnt-masterd -c "Ganeti Luxid User" gnt-luxid +%useradd -u 303 -d /var/lib/ganeti -g gnt-rapi -G gnt-daemons,gnt-admin -c "Ganeti RAPI User" gnt-rapi + %post /sbin/chkconfig --add ganeti-noded %service ganeti-noded restart @@ -205,6 +235,18 @@ fi %systemd_preun ganeti.target ganeti-noded.service ganeti-masterd.service ganeti-rapi.service ganeti-confd.service ganeti-luxid.service ganeti-mond.service %postun +if [ "$1" = "0" ]; then + %userremove gnt-rapi + %userremove gnt-luxid + %userremove gnt-confd + %userremove gnt-masterd + %groupremove gnt-admin + %groupremove gnt-masterd + %groupremove gnt-rapi + %groupremove gnt-luxid + %groupremove gnt-confd + %groupremove gnt-daemons +fi %systemd_reload %files @@ -217,6 +259,7 @@ fi %attr(754,root,root) /etc/rc.d/init.d/ganeti-noded %attr(754,root,root) /etc/rc.d/init.d/ganeti-rapi %config(noreplace) %verify(not md5 mtime size) /etc/sysconfig/ganeti +%config(noreplace) %verify(not md5 mtime size) /etc/sudoers.d/ganeti %dir %{_sysconfdir}/ganeti %{systemdunitdir}/ganeti.target %{systemdunitdir}/ganeti-confd.service @@ -227,7 +270,9 @@ fi %{systemdunitdir}/ganeti-rapi.service %{systemdtmpfilesdir}/ganeti.conf /etc/cron.d/ganeti +%attr(640,root,root) %config(noreplace) %verify(not md5 mtime size) /etc/logrotate.d/ganeti %dir %{_datadir}/ganeti +%dir %{_datadir}/ganeti/extstorage %dir %{_datadir}/ganeti/os %dir %{_libdir}/ganeti %attr(755,root,root) %{_libdir}/ganeti/check-cert-expired @@ -236,9 +281,13 @@ fi %attr(755,root,root) %{_libdir}/ganeti/import-export %attr(755,root,root) %{_libdir}/ganeti/kvm-ifup %attr(755,root,root) %{_libdir}/ganeti/mon-collector +%attr(755,root,root) %{_libdir}/ganeti/net-common %attr(755,root,root) %{_libdir}/ganeti/node-daemon-setup %attr(755,root,root) %{_libdir}/ganeti/prepare-node-join +%attr(755,root,root) %{_libdir}/ganeti/vif-ganeti +%dir %{_libdir}/ganeti/extstorage %dir %{_libdir}/ganeti/iallocators +%dir %{_libdir}/ganeti/os %dir %{_libdir}/ganeti/tools %attr(755,root,root) %{_libdir}/ganeti/tools/burnin %attr(755,root,root) %{_libdir}/ganeti/tools/cfgshell @@ -268,6 +317,7 @@ fi %attr(755,root,root) %{_sbindir}/ganeti-watcher %attr(755,root,root) %{_sbindir}/gnt-backup %attr(755,root,root) %{_sbindir}/gnt-cluster +%attr(755,root,root) %{_sbindir}/gnt-config-backup %attr(755,root,root) %{_sbindir}/gnt-debug %attr(755,root,root) %{_sbindir}/gnt-group %attr(755,root,root) %{_sbindir}/gnt-instance @@ -319,12 +369,17 @@ fi %{py_sitescriptdir}/ganeti/rapi/*.py* %dir %{py_sitescriptdir}/ganeti/server %{py_sitescriptdir}/ganeti/server/*.py* +%dir %{py_sitescriptdir}/ganeti/storage +%{py_sitescriptdir}/ganeti/storage/*.py* %dir %{py_sitescriptdir}/ganeti/tools %{py_sitescriptdir}/ganeti/tools/*.py* %dir %{py_sitescriptdir}/ganeti/utils %{py_sitescriptdir}/ganeti/utils/*.py* %dir %{py_sitescriptdir}/ganeti/watcher %{py_sitescriptdir}/ganeti/watcher/*.py* +%dir %attr(755,gnt-masterd,gnt-masterd) /var/lib/ganeti +%dir %attr(770,gnt-masterd,gnt-daemons) /var/log/ganeti +%dir %attr(775,gnt-masterd,gnt-daemons) /var/run/ganeti %files htools %defattr(644,root,root,755)