+# TODO
+# - /usr/share/hal/fdi/policy/20thirdparty/80-apcupsd-ups-policy.fdi
#
# Conditional build:
-%bcond_without test # without TEST support
-%bcond_without usb # without USB support
+%bcond_without cgi # without CGI program support
+%bcond_without gapcmon # without gapcmon GUI
%bcond_without net # without network support
-%bcond_without cgi # with CGI program support
%bcond_with snmp # with SNMP support
+%bcond_without test # without TEST support
+%bcond_without usb # without USB support
#
Summary: Power management software for APC UPS hardware
-Summary(pl): Oprogramowanie do zarz±dzania energi± dla UPS-ów APC
+Summary(pl.UTF-8): Oprogramowanie do zarządzania energią dla UPS-ów APC
Name: apcupsd
-Version: 3.12.1
-Release: 0.1
+Version: 3.14.10
+Release: 1
License: GPL v2
Group: Networking/Daemons
-Source0: http://dl.sourceforge.net/apcupsd/%{name}-%{version}.tar.gz
-# Source0-md5: d2e710176430a28d624500e145d9ffe3
+Source0: http://downloads.sourceforge.net/apcupsd/%{name}-%{version}.tar.gz
+# Source0-md5: 5928822d855c5cf7ac29655e3e0b8c23
Source1: %{name}.init
Source2: %{name}.logrotate
Source3: %{name}.sysconfig
Patch0: %{name}-configure.patch
+Patch1: %{name}-pcnet-seconds.patch
URL: http://www.apcupsd.com/
+%{?with_gapcmon:BuildRequires: GConf2-devel >= 2.0}
BuildRequires: autoconf
BuildRequires: automake
+BuildRequires: gd-devel
+%{?with_gapcmon:BuildRequires: gtk+2-devel >= 2:2.4.0}
+BuildRequires: man
%{?with_snmp:BuildRequires: net-snmp-devel}
+BuildRequires: pkgconfig
+BuildRequires: rpmbuild(macros) >= 1.268
+BuildRequires: util-linux
Requires(post): fileutils
Requires(post,preun): /sbin/chkconfig
Requires: rc-scripts
BuildRoot: %{tmpdir}/%{name}-%{version}-root-%(id -u -n)
%define _sysconfdir /etc/apcupsd
-%define _cgidir /home/services/httpd/cgi-bin
+%define _cgidir /home/services/httpd/cgi-bin
%description
UPS power management under Linux for APCC Products. It allows your
SmartUPS v/s, or SmartUPS, and then properly executes a controlled
shutdown during an extended power failure.
-%description -l pl
-Oprogramowanie do zarz±dzania energi± dla UPS-ów APC. Pozwala
-komputerowi dzia³aæ po awarii zasilania przez okre¶lony czas lub czas
-¿ycia akumulatorów w BackUPS, BackUPS Pro, SmartUPS v/s, SmartUPS oraz
-odpowiednio uruchamia kontrolowany shutdown przy d³u¿szej awarii
+%description -l pl.UTF-8
+Oprogramowanie do zarządzania energią dla UPS-ów APC. Pozwala
+komputerowi działać po awarii zasilania przez określony czas lub czas
+życia akumulatorów w BackUPS, BackUPS Pro, SmartUPS v/s, SmartUPS oraz
+odpowiednio uruchamia kontrolowany shutdown przy dłuższej awarii
zasilania.
-%package cgi
-Summary: upsstats - Web-based UPS status viewer
-Summary(pl): upsstats - oparta na WWW przegl±darka stanu UPS-a
-Group: Applications/Networking
-Requires: webserver
+%package cgi
+Summary: upsstats - Web-based UPS status viewer
+Summary(pl.UTF-8): upsstats - oparta na WWW przeglądarka stanu UPS-a
+Group: Applications/Networking
+Requires: webserver
%description cgi
upsstats.cgi builds a lightweight web page containing basic UPS status
information.
-%description cgi -l pl
-upsstats.cgi tworzy lekk± stronê WWW zawieraj±c± podstawowe informacje
+%description cgi -l pl.UTF-8
+upsstats.cgi tworzy lekką stronę WWW zawierającą podstawowe informacje
o stanie UPS-a.
+%package gapcmon
+Summary: Apcupsd GUI monitoring application
+Summary(pl.UTF-8): Aplikacja GUI monitorowania Apcupsd
+Group: X11/Applications
+
+%description gapcmon
+GNOME/GTK+ based application which integrates into most desktop panels
+(not just GNOME). It monitors one or more Apcupsd instances using
+Apcupsd's NIS networking server. The status of each UPS is shown with
+a icon.
+
+%description gapcmon -l pl.UTF-8
+Oparta na GNOME/GTK+ aplikacja, która integruje się z panelami (nie
+tylko Gnome). Monitoruje jedną bądź kilka instancji Apcupsd za pomocą
+serwera NIS. Status każdego UPS-a przedstawia ikona.
+
%prep
%setup -q
-#%patch0 -p1
+%patch0 -p1
+%patch1 -p1
+for i in configure.in aclocal.m4 config.h.in; do install autoconf/$i .;done
+cp -f %{_datadir}/automake/config.sub autoconf
%build
-cd autoconf
-cp -f /usr/share/automake/config.sub .
%{__autoconf}
-cp -f configure ..
-cd ..
-
%configure \
+ APCUPSD_MAIL="/bin/mail" \
+ SHUTDOWN="/sbin/shutdown" \
+ WALL="%{_bindir}/wall" \
--with-log-dir=%{_var}/log \
--with-stat-dir=%{_var}/lib/apcupsd \
%if %{with cgi}
%{?with_test:--enable-test} \
%if %{with net}
--enable-net \
- --enable-master-slave \
%endif
+ %{?with_gapcmon:--enable-gapcmon} \
%{?with_snmp:--enable-snmp} \
%{?with_usb:--enable-usb}
%post
/sbin/chkconfig --add apcupsd
-if [ -f /var/lock/subsys/apcupsd ]; then
- /etc/rc.d/init.d/apcupsd restart >&2
-else
- echo "Run \"/etc/rc.d/init.d/apcupsd start\" to start apcupsd daemon."
-fi
+%service apcupsd restart "apcupsd daemon"
%preun
if [ "$1" = "0" ]; then
- if [ -f /var/lock/subsys/apcupsd ]; then
- /etc/rc.d/init.d/apcupsd stop >&2
- fi
+ %service apcupsd stop
/sbin/chkconfig --del apcupsd
fi
%files
%defattr(644,root,root,755)
%doc ChangeLog Developers
-%attr(755,root,root) %{_sbindir}/*
+%attr(755,root,root) %{_sbindir}/apcaccess
+%attr(755,root,root) %{_sbindir}/apctest
+%attr(755,root,root) %{_sbindir}/apcupsd
+%attr(755,root,root) %{_sbindir}/smtp
%attr(640,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/apcupsd.conf
%attr(640,root,root) %config(noreplace) %verify(not md5 mtime size) /etc/sysconfig/apcupsd
%attr(754,root,root) %{_sysconfdir}/apccontrol
-%attr(754,root,root) %{_sysconfdir}/changeme
-%attr(754,root,root) %{_sysconfdir}/commfailure
-%attr(754,root,root) %{_sysconfdir}/commok
-#%attr(754,root,root) %{_sysconfdir}/mainsback
-%attr(754,root,root) %{_sysconfdir}/masterconnect
-%attr(754,root,root) %{_sysconfdir}/mastertimeout
-%attr(754,root,root) %{_sysconfdir}/onbattery
-%attr(754,root,root) %{_sysconfdir}/offbattery
+%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/changeme
+%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/commfailure
+%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/commok
+#%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/mainsback
+%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/onbattery
+%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/offbattery
%if %{with cgi}
%config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/hosts.conf
%config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/multimon.conf
%dir /var/lib/apcupsd
%attr(640,root,root) %ghost /var/log/apcupsd.events
%attr(640,root,root) %ghost /var/lib/apcupsd/apcupsd.status
-%{_mandir}/man8/apcupsd.*
+%{_mandir}/man8/apcupsd.8*
+%{_mandir}/man8/apctest.8*
+%{_mandir}/man8/apcaccess.8*
+%{_mandir}/man8/apccontrol.8*
+%{_mandir}/man5/apcupsd.conf.5*
+%if %{with cgi}
%files cgi
%defattr(644,root,root,755)
%attr(755,root,root) %{_cgidir}/*.cgi
+%endif
+
+%if %{with gapcmon}
+%files gapcmon
+%defattr(644,root,root,755)
+%attr(755,root,root) %{_bindir}/gapcmon
+%{_desktopdir}/gapcmon.desktop
+%{_pixmapsdir}/*.png
+%endif