+#
+# Conditional build:
+%bcond_without cgi # without CGI program support
+%bcond_without gapcmon # without gapcmon GUI
+%bcond_without net # without network support
+%bcond_with snmp # with SNMP support
+%bcond_without test # without TEST support
+%bcond_without usb # without USB support
+
Summary: Power management software for APC UPS hardware
-Summary(pl): Oprogramowanie do zarz±dzania energi± dla UPS-ów APC
+Summary(pl.UTF-8): Oprogramowanie do zarządzania energią dla UPS-ów APC
Name: apcupsd
-Version: 3.8.1
-Release: 3
+Version: 3.14.10
+Release: 2
License: GPL v2
Group: Networking/Daemons
-Group(de): Netzwerkwesen/Server
-Group(pl): Sieciowe/Serwery
-Source0: http://www.sibbald.com/apcupsd/download/%{name}-%{version}.tar.gz
-Patch0: %{name}-paths.patch
-Patch1: %{name}-pld.patch
-#Patch1: apcups-makefile.patch
-#Patch2: %{name}-Makefile-fix.patch
-URL: http://www.sibbald.com/apcupsd/
-Prereq: chkconfig
+Source0: http://downloads.sourceforge.net/apcupsd/%{name}-%{version}.tar.gz
+# Source0-md5: 5928822d855c5cf7ac29655e3e0b8c23
+Source1: %{name}.init
+Source2: %{name}.logrotate
+Source3: %{name}.sysconfig
+Patch0: %{name}-configure.patch
+Patch1: %{name}-pcnet-seconds.patch
+URL: http://www.apcupsd.com/
+%{?with_gapcmon:BuildRequires: GConf2-devel >= 2.0}
+BuildRequires: autoconf
+BuildRequires: automake
+BuildRequires: gd-devel
+%{?with_gapcmon:BuildRequires: gtk+2-devel >= 2:2.4.0}
+BuildRequires: man
+%{?with_snmp:BuildRequires: net-snmp-devel}
+BuildRequires: pkgconfig
+BuildRequires: rpmbuild(macros) >= 1.268
+BuildRequires: util-linux
+Requires(post): fileutils
+Requires(post,preun): /sbin/chkconfig
+Requires: rc-scripts
BuildRoot: %{tmpdir}/%{name}-%{version}-root-%(id -u -n)
-#Icon: apcupsd-logo.xpm
%define _sysconfdir /etc/apcupsd
+%define _cgidir /home/services/httpd/cgi-bin
%description
UPS power management under Linux for APCC Products. It allows your
SmartUPS v/s, or SmartUPS, and then properly executes a controlled
shutdown during an extended power failure.
-%description -l pl
-Oprogramowanie do zarz±dzania energi± dla UPS-ów APC. Pozwala
-komputerowi dzia³aæ po awarii zasilania przez okre¶lony czas lub czas
-¿ycia akumulatorów w BackUPS, BackUPS Pro, SmartUPS v/s, SmartUPS oraz
-odpowiednio uruchamia kontrolowany shutdown przy d³u¿szej awarii
+%description -l pl.UTF-8
+Oprogramowanie do zarządzania energią dla UPS-ów APC. Pozwala
+komputerowi działać po awarii zasilania przez określony czas lub czas
+życia akumulatorów w BackUPS, BackUPS Pro, SmartUPS v/s, SmartUPS oraz
+odpowiednio uruchamia kontrolowany shutdown przy dłuższej awarii
zasilania.
+%package cgi
+Summary: upsstats - Web-based UPS status viewer
+Summary(pl.UTF-8): upsstats - oparta na WWW przeglądarka stanu UPS-a
+Group: Applications/Networking
+Requires: webserver
+
+%description cgi
+upsstats.cgi builds a lightweight web page containing basic UPS status
+information.
+
+%description cgi -l pl.UTF-8
+upsstats.cgi tworzy lekką stronę WWW zawierającą podstawowe informacje
+o stanie UPS-a.
+
+%package gapcmon
+Summary: Apcupsd GUI monitoring application
+Summary(pl.UTF-8): Aplikacja GUI monitorowania Apcupsd
+Group: X11/Applications
+URL: http://gapcmon.sourceforge.net/
+
+%description gapcmon
+GNOME/GTK+ based application which integrates into most desktop panels
+(not just GNOME). It monitors one or more Apcupsd instances using
+Apcupsd's NIS networking server. The status of each UPS is shown with
+a icon.
+
+%description gapcmon -l pl.UTF-8
+Oparta na GNOME/GTK+ aplikacja, która integruje się z panelami (nie
+tylko Gnome). Monitoruje jedną bądź kilka instancji Apcupsd za pomocą
+serwera NIS. Status każdego UPS-a przedstawia ikona.
+
%prep
%setup -q
%patch0 -p1
%patch1 -p1
-#%patch2 -p0
+for i in configure.in aclocal.m4 config.h.in; do install autoconf/$i .;done
+cp -f %{_datadir}/automake/config.sub autoconf
%build
-%configure
+%{__autoconf}
+%configure \
+ APCUPSD_MAIL="/bin/mail" \
+ SHUTDOWN="/sbin/shutdown" \
+ WALL="%{_bindir}/wall" \
+ --with-log-dir=%{_var}/log \
+ --with-stat-dir=%{_var}/lib/apcupsd \
+%if %{with cgi}
+ --enable-cgi \
+ --with-cgi-bin=/home/services/httpd/cgi-bin \
+%endif
+ %{?with_test:--enable-test} \
+%if %{with net}
+ --enable-net \
+%endif
+ %{?with_gapcmon:--enable-gapcmon} \
+ %{?with_snmp:--enable-snmp} \
+ %{?with_usb:--enable-usb}
+
%{__make}
%install
rm -rf $RPM_BUILD_ROOT
-install -d $RPM_BUILD_ROOT{%{_sbindir},%{_bindir},%{_mandir}/man8,%{_sysconfdir},/etc/rc.d/init.d,/var/log,/var/lib/apcupsd}
+install -d $RPM_BUILD_ROOT/etc/{apcupsd,logrotate.d,rc.d/init.d,sysconfig} \
+ $RPM_BUILD_ROOT/var/{log,lib/apcupsd}
-install apcupsd apcnetd $RPM_BUILD_ROOT%{_sbindir}
-install apcaccess $RPM_BUILD_ROOT%{_bindir}
-install etc/* $RPM_BUILD_ROOT%{_sysconfdir}
-install distributions/pld/apccontrol.sh $RPM_BUILD_ROOT%{_sysconfdir}/apccontrol
-install distributions/pld/apcupsd $RPM_BUILD_ROOT/etc/rc.d/init.d/apcupsd
-install doc/apcupsd.man $RPM_BUILD_ROOT%{_mandir}/man8
-tar czf doc.tar.gz doc
+%{__make} install \
+ DESTDIR=$RPM_BUILD_ROOT
-touch ${RPM_BUILD_ROOT}/var/log/apcupsd.log
-touch ${RPM_BUILD_ROOT}/var/lib/apcupsd/apcupsd.status
-touch ${RPM_BUILD_ROOT}/var/lib/apcupsd/apcupsd.events
+install -p %{SOURCE1} $RPM_BUILD_ROOT/etc/rc.d/init.d/apcupsd
+cp -p %{SOURCE2} $RPM_BUILD_ROOT/etc/logrotate.d/apcupsd
+cp -p %{SOURCE3} $RPM_BUILD_ROOT/etc/sysconfig/apcupsd
+
+touch $RPM_BUILD_ROOT/var/log/apcupsd.events
+touch $RPM_BUILD_ROOT/var/lib/apcupsd/apcupsd.status
+
+cat > $RPM_BUILD_ROOT/etc/rc.d/init.d/halt << EOF
+#!/bin/sh
+exec /etc/rc.d/init.d/apcupsd powerdown
+EOF
+
+# no hal
+%{__rm} $RPM_BUILD_ROOT%{_datadir}/hal/fdi/policy/20thirdparty/80-apcupsd-ups-policy.fdi
%clean
rm -rf $RPM_BUILD_ROOT
%post
-/sbin/ldconfig
/sbin/chkconfig --add apcupsd
-
-#if !(grep /sbin/powersc /etc/rc.d/init.d/halt > /dev/null); then
-cp -f /etc/rc.d/init.d/halt /etc/rc.d/init.d/halt.rpmorig
-#sed -e '/# Now halt or reboot./i\' \
-# -e '\
-# See if this is a powerfail situation.\
-
-echo '
-if [ -f /etc/apcupsd/powerfail ]; then\
- echo "APCUPSD to the Rescue!"\
- echo\
- /etc/apcupsd/apccontrol killpower \
- echo\
- sleep 120\
- exit 1\
-fi\
-' > /etc/rc.d/init.d/halt
-#' /etc/rc.d/init.d/halt.rpmorig > /etc/rc.d/init.d/halt
-#fi
+%service apcupsd restart "apcupsd daemon"
%preun
if [ "$1" = "0" ]; then
- chkconfig --del apcupsd
+ %service apcupsd stop
+ /sbin/chkconfig --del apcupsd
fi
%files
%defattr(644,root,root,755)
-%doc doc.tar.gz
-%doc ChangeLog
-%{_mandir}/man8/apcupsd.*
-%attr(755,root,root) %{_sbindir}/*
-%attr(755,root,root) %{_bindir}/*
-#%attr(755,root,root) %config /sbin/powersc
-%attr(640,root,root) %config(noreplace) %{_sysconfdir}/apcupsd.conf
+%doc ChangeLog Developers
+%attr(755,root,root) %{_sbindir}/apcaccess
+%attr(755,root,root) %{_sbindir}/apctest
+%attr(755,root,root) %{_sbindir}/apcupsd
+%attr(755,root,root) %{_sbindir}/smtp
+%attr(640,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/apcupsd.conf
+%attr(640,root,root) %config(noreplace) %verify(not md5 mtime size) /etc/sysconfig/apcupsd
+%attr(754,root,root) %{_sysconfdir}/apccontrol
+%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/changeme
+%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/commfailure
+%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/commok
+#%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/mainsback
+%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/onbattery
+%attr(754,root,root) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/offbattery
+%if %{with cgi}
+%config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/hosts.conf
+%config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/multimon.conf
+%{_sysconfdir}/apcupsd.css
+%endif
%attr(754,root,root) /etc/rc.d/init.d/apcupsd
-%ghost /var/log/apcupsd.log
-%ghost /var/lib/apcupsd/apcupsd.status
-%ghost /var/lib/apcupsd/apcupsd.events
+%attr(754,root,root) /etc/rc.d/init.d/halt
+%attr(640,root,root) %config(noreplace) %verify(not md5 mtime size) /etc/logrotate.d/apcupsd
+%dir %{_sysconfdir}
+%dir /var/lib/apcupsd
+%attr(640,root,root) %ghost /var/log/apcupsd.events
+%attr(640,root,root) %ghost /var/lib/apcupsd/apcupsd.status
+%{_mandir}/man8/apcupsd.8*
+%{_mandir}/man8/apctest.8*
+%{_mandir}/man8/apcaccess.8*
+%{_mandir}/man8/apccontrol.8*
+%{_mandir}/man5/apcupsd.conf.5*
+
+%if %{with cgi}
+%files cgi
+%defattr(644,root,root,755)
+%attr(755,root,root) %{_cgidir}/*.cgi
+%endif
+
+%if %{with gapcmon}
+%files gapcmon
+%defattr(644,root,root,755)
+%attr(755,root,root) %{_bindir}/gapcmon
+%{_desktopdir}/gapcmon.desktop
+%{_pixmapsdir}/*.png
+%endif