]> git.pld-linux.org Git - packages/PowerChutePlus.git/blobdiff - PowerChutePlus.spec
- should groupmod if NOT equal, I think
[packages/PowerChutePlus.git] / PowerChutePlus.spec
index f77882f5bda35ffcc0f4ab50eac0574ea1410793..3fb182a2df6d902f96dad1d5e8e29171b6a06ce5 100644 (file)
@@ -1,22 +1,36 @@
 Summary:       UPS management software for APC UPS models
-Summary(pl):   Oprogramowanie do obs³ugi UPS-ów APC
+Summary(pl.UTF-8):     Oprogramowanie do obsługi UPS-ów APC
 Name:          PowerChutePlus
 Version:       4.5.3
-Release:       1
+Release:       2
 License:       (c) 1999 APC, inc.
 Group:         Applications/System
 Source0:       ftp://ftp.apcc.com/apc/public/software/unix/linux/pcplus/453/pcplus_453_caldera.tar
+# Source0-md5: 5eb99efd5561694b9f692aa713bd974d
 Source1:       ftp://ftp.apcc.com/apc/public/software/unix/linux/pcplus/453/pc453ug.pdf
+# Source1-md5: 0c2a621adcad8fdcb6064ed3cb042711
 Source2:       upsd.init
 Source3:       %{name}-xpowerchute.sh
 Source4:       %{name}-Config.sh
 Source5:       %{name}-powerchute.ini
 Source6:       %{name}-powerchute.ini_templ
 Source7:       ftp://ftp.apcc.com/apc/public/software/unix/linux/pcplus/settings.pdf
+# Source7-md5: c69abad141a836fd12ced0cc39049dc6
 Patch0:                %{name}-fix-sh.patch
-ExclusiveOS:   linux
+BuildRequires: rpmbuild(macros) >= 1.268
+Requires(post,preun):  /sbin/chkconfig
+Requires(postun):      /usr/sbin/groupdel
+Requires(postun):      /usr/sbin/userdel
+Requires(pre): /bin/id
+Requires(pre): /usr/bin/getgid
+Requires(pre): /usr/sbin/groupadd
+Requires(pre): /usr/sbin/groupmod
+Requires(pre): /usr/sbin/useradd
+Requires(pre): /usr/sbin/usermod
+Requires:      rc-scripts
+Provides:      group(pwrchute)
+Provides:      user(pwrchute)
 ExclusiveArch: %{ix86}
-Prereq:                chkconfig
 BuildRoot:     %{tmpdir}/%{name}-%{version}-root-%(id -u -n)
 
 %description
@@ -24,26 +38,23 @@ This program allows users to safely shut down their system in response
 to power failures and other power events. It also allows users to
 configure and manage UPS models.
 
-Please note that /usr/lib/powerchute/Config.sh should be run in order
+Please note that %{_libdir}/powerchute/Config.sh should be run in order
 to configure PowerChute plus.
 
-%description -l pl
-Ten program pozwala u¿ytkownikom bezpiecznie wy³±czyæ system w
-przypadku awarii zasilania. Pozwala tak¿e na skonfigurowanie UPS.
+%description -l pl.UTF-8
+Ten program pozwala użytkownikom bezpiecznie wyłączyć system w
+przypadku awarii zasilania. Pozwala także na skonfigurowanie UPS.
 
-Uwaga: aby skonfigurowaæ PowerChute Plus nale¿y uruchomiæ
+Uwaga: aby skonfigurować PowerChute Plus należy uruchomić
 /usr/lib/powerchute/Config.sh .
 
 %prep
 %setup -q -c
-for i in BI_LINUX CI_LINUX COMMON FI_LINUX HELP ; do
+for i in BI_LINUX CI_LINUX COMMON FI_LINUX HELP; do
        tar xf $i
 done
 %patch0 -p1
 
-%build
-# No build, binary package
-
 %install
 rm -rf $RPM_BUILD_ROOT
 install -d $RPM_BUILD_ROOT{%{_sbindir},%{_libdir}/powerchute} \
@@ -58,7 +69,7 @@ install %{SOURCE4} $RPM_BUILD_ROOT%{_libdir}/powerchute/Config.sh
 install %{SOURCE6} $RPM_BUILD_ROOT%{_libdir}/powerchute/powerchute.ini_templ
 install %{SOURCE5} $RPM_BUILD_ROOT%{_sysconfdir}/powerchute.ini
 
-ln -sf %{_sysconfdir}/powerchute.ini $RPM_BUILD_ROOT%{_libdir}/powerchute/
+ln -sf %{_sysconfdir}/powerchute.ini $RPM_BUILD_ROOT%{_libdir}/powerchute
 
 install _upsd $RPM_BUILD_ROOT%{_sbindir}/upsd
 
@@ -80,58 +91,53 @@ install upsoff $RPM_BUILD_ROOT%{_libdir}/powerchute
 install upswrite $RPM_BUILD_ROOT%{_libdir}/powerchute
 install wall.sh $RPM_BUILD_ROOT%{_libdir}/powerchute
 install what_os.sh $RPM_BUILD_ROOT%{_libdir}/powerchute
-install pwrchute.uid $RPM_BUILD_ROOT%{_prefix}/X11R6/lib/X11/uid/
+install pwrchute.uid $RPM_BUILD_ROOT%{_prefix}/X11R6/lib/X11/uid
 
 install pwrchute.ad $RPM_BUILD_ROOT%{_prefix}/X11R6/lib/X11/app-defaults/pwrchute
 
-ln -sf /var/run/upsd.pid $RPM_BUILD_ROOT%{_libdir}/powerchute/
-ln -sf /var/run/bkupsd.pid $RPM_BUILD_ROOT%{_libdir}/powerchute/
-
-gzip -9nf language.txt readme_apache
+ln -sf /var/run/upsd.pid $RPM_BUILD_ROOT%{_libdir}/powerchute
+ln -sf /var/run/bkupsd.pid $RPM_BUILD_ROOT%{_libdir}/powerchute
 
 %clean
 rm -rf $RPM_BUILD_ROOT
 
 %pre
-if ! id -g pwrchute > /dev/null 2>&1 ; then
-       %{_sbindir}/groupadd -g 68 pwrchute
-fi
-if ! id -u pwrchute > /dev/null 2>&1 ; then
-       %{_sbindir}/useradd -u 68 -g 68 -d /dev/null -s /bin/false -c "PowerChute Plus" pwrchute
+# move to trigger?
+if [ -n "`/usr/bin/getgid pwrchute 2>/dev/null`" ] && [ "`/usr/bin/getgid pwrchute`" != 233 ]; then
+       /usr/sbin/groupmod -g 233 pwrchute
+       chgrp pwrchute %{_sysconfdir}/powerchute.ini
+       /usr/sbin/usermod -u 233 -g 233 pwrchute
 fi
+%groupadd -g 233 pwrchute
+%useradd -u 233 -g 233 -d /usr/share/empty -s /bin/false -c "PowerChute Plus" pwrchute
 
 %post
 /sbin/chkconfig --add upsd
-if [ -f /var/lock/subsys/upsd ]; then
-       /etc/rc.d/init.d/upsd restart 1>&2
-else
-       echo "Type \"/etc/rc.d/init.d/upsd start\" to start UPSd server" 1>&2
-fi
+%service upsd restart "UPSd server"
 cd %{_libdir}/powerchute
 ./machine_id
 echo "You should run %{_libdir}/powerchute/Config.sh to configure PowerChute plus"
 echo "Remember to set the password for pwrchute account"
-       
+
 %preun
 if [ "$1" = "0" ]; then
-       if [ -f /var/lock/subsys/upsd ]; then
-               /etc/rc.d/init.d/upsd stop 1>&2
-       fi
+       %service upsd stop
        /sbin/chkconfig --del upsd
 fi
 
 %postun
 if [ "$1" = "0" ]; then
-       %{_sbindir}/userdel pwrchute
-       %{_sbindir}/groupdel pwrchute
+       %userremove pwrchute
+       %groupremove pwrchute
 fi
 
 %files
 %defattr(644,root,root,755)
-%doc help/* apachesh.pdf language.txt.gz readme_apache.gz pc453ug.pdf settings.pdf
+%doc help/* apachesh.pdf language.txt readme_apache pc453ug.pdf settings.pdf
 %attr(754,root,root) /etc/rc.d/init.d/upsd
-%config(noreplace) %verify(not size mtime md5) %{_sysconfdir}/powerchute.ini
+%attr(640,root,pwrchute) %config(noreplace) %verify(not md5 mtime size) %{_sysconfdir}/powerchute.ini
 %attr(755,root,root) %{_sbindir}/upsd
+%dir %{_libdir}/powerchute
 %attr(755,root,root) %{_libdir}/powerchute/Config.sh
 %attr(755,root,root) %{_libdir}/powerchute/_xpwrchute
 %attr(755,root,root) %{_libdir}/powerchute/addpage.sh
@@ -156,5 +162,5 @@ fi
 %attr(755,root,root) %{_prefix}/X11R6/bin/xpowerchute
 %{_prefix}/X11R6/lib/X11/app-defaults/*
 %{_prefix}/X11R6/lib/X11/uid/*
-%config(noreplace) %verify(not size mtime md5) %{_libdir}/powerchute/upsd.pid
-%config(noreplace) %verify(not size mtime md5) %{_libdir}/powerchute/bkupsd.pid
+%config(noreplace) %verify(not md5 mtime size) %{_libdir}/powerchute/upsd.pid
+%config(noreplace) %verify(not md5 mtime size) %{_libdir}/powerchute/bkupsd.pid
This page took 0.102524 seconds and 4 git commands to generate.