1 [ Ups ]
2  SignallingType = smart
3  PortName = /dev/ttyS0
4  AutoUpsRebootEnabled = Yes
5  AllowedPortNames = /dev/ttyS0,/dev/ttyS1
6  CableType = Normal
7  
8
9 [ EventLogging ]
10  EventLogEnabled = Yes
11  EventLogName = /var/log/powerchute.log
12  EventLogMaxSize = 50000
13
14
15 [ DataLogging ]
16  DataLogEnabled = Yes
17  DataLogName = /var/log/powerchute.dat
18  DataLogMaxSize = 50000
19  DataLogInterval = 600
20
21 [ ErrorLogging ]
22  ErrorLogEnabled = Yes
23  ErrorLogName = /var/log/powerchute.err
24  ErrorLogMaxSize = 50000
25
26
27 [ Messaging ]
28  MessageDelay = 5
29  MessageInterval = 30
30
31
32 [ SelfTests ]
33  EnableSelfTests = Yes
34  SelfTestDay = MONDAY
35  SelfTestSchedule = At turn on
36  SelfTestTime = 12:00 PM
37  
38
39 [ Shutdown ]
40  ShutdownDelay = 30
41  AdminShutdownDelay = 900
42  DailyShutdownEnabled = No
43  DailyShutdownTime = 6:00 PM
44  DailyWakeupTime = 7:00 AM
45  WeeklyShutdownEnabled = No
46  WeeklyShutdownDay = Friday
47  WeeklyShutdownTime = 6:00 PM
48  WeeklyWakeUpDay = Monday
49  WeeklyWakeUpTime = 7:00 AM
50
51 [ Server ]
52  HostName =
53
54 [ UserInterface ]
55  TemperatureUnits = Celsius
56  SoundEffects = No
57
58 [ BatteryCalibration ]
59  Enabled = No
60  BatteryCalibrationDay = Monday
61  BatteryCalibrationTime = 07:00 AM
62
63 [ Devices ]
64  MeasureUps = NO
65
66 [ EventText ]
67  100000 = *** PowerChute PLUS Version 4.5.2 (glibc) Started ***
68  100100 = *** PowerChute PLUS Stopped ***
69  100200 = Communication established
70  100300 = Normal power restored: UPS on line
71  100400 = UPS self-test passed
72  100401 = Scheduled UPS self-test passed
73  100402 = User initiated UPS self-test passed
74  100403 = Self-test at UPS passed
75  100500 = Administrative shutdown started
76  100501 = Administrative shutdown: User initiated
77  100502 = Administrative shutdown: Weekly shutdown
78  100503 = Administrative shutdown: Daily shutdown
79  100600 = Shutdown cancelled
80  100601 = User initiated shutdown cancelled
81  100602 = Weekly administrative shutdown cancelled
82  100603 = Daily administrative shutdown cancelled
83  100700 = UPS returned from low battery condition
84  100701 = UPS returned from low battery condition: #BATTERY_CAPACITY#%
85  100900 = UPS batteries no longer need replacing
86  101000 = Contact #CONTACT_NUMBER# normal (#NORMAL_POSITION#): #USER_COMMENT#
87  101300 = UPS overload condition solved
88  101400 = UPS run time calibration initiated
89  101500 = UPS run time calibration completed
90  101600 = Shutdown started
91  101601 = User initiated shutdown started
92  101602 = Weekly administrative shutdown started
93  101603 = Daily administrative shutdown started
94  101700 = UPS returned from bypass
95  101800 = Smart Cell Signal Restored
96  110000 = Ambient temperature back within thresholds
97  110100 = Ambient humidity back within thresholds
98
99
100  200000 = UPS on battery
101  200001 = UPS on battery: High input line voltage #MAX_VOLTAGE# V
102  200002 = UPS on battery: Brownout #MIN_VOLTAGE# V
103  200003 = UPS on battery: Blackout #MIN_VOLTAGE# V
104  200004 = UPS on battery: Small momentary sag #MIN_VOLTAGE# V
105  200006 = UPS on battery: Deep momentary sag #MIN_VOLTAGE# V
106  200005 = UPS on battery: Small momentary spike #MAX_VOLTAGE# V
107  200007 = UPS on battery: Large momentary spike #MAX_VOLTAGE# V
108  200008 = UPS on battery: Simulated power failure
109  200100 = System shutdown
110  200200 = UPS enabling SmartBoost
111  200300 = Low battery condition
112  200301 = Low battery condition: #BATTERY_CAPACITY#%
113  200400 = UPS run time calibration cancelled
114  200401 = UPS run time calibration cancelled by user
115  200402 = UPS run time calibration cancelled by power failure
116  200403 = UPS unable to perform run time calibration: Capacity < 100%
117  201301 = UPS on bypass: user set via software or panel
118  201302 = GSUB_CHANGE13_HERE
119
120
121  300000 = Unable to communicate with UPS
122  300100 = UPS output overload
123  300200 = UPS self-test failed
124  300201 = Scheduled UPS self-test failed: Bad battery
125  300202 = Scheduled UPS self-test failed: Invalid test
126  300203 = User initiated self-test failed: Bad battery
127  300204 = User initiated self-test failed: Invalid test
128  300205 = Self-test at UPS failed: Bad battery
129  300206 = Self-test at UPS failed: Invalid test
130  300300 = UPS battery is discharged
131  300301 = UPS battery is discharged: #BATTERY_CAPACITY#%
132  300400 = Communication lost while on battery
133  300600 = Contact #CONTACT_NUMBER# fault (#CONTACT_POSITION#): #USER_COMMENT#
134  301000 = Check installation of Smart Cell signal cable
135  301300 = UPS on bypass internal temp over limit
136  301301 = UPS on bypass battery charger failure
137  301302 = UPS on bypass: severe DC imbalance overload
138  301303 = UPS on bypass: output voltage outside limits
139  301304 = UPS on bypass: top module fan needs repair
140  301400 = Base module fan needs repair
141  301500 = Base module bypass power supply needs repair
142  301600 = UPS battery needs replacing
143
144  310001 = Below lower ambient temperature threshold of #LOW_THRESHOLD#
145  310002 = Exceeded upper ambient temperature threshold of #HIGH_THRESHOLD#
146  310101 = Below humidity threshold of #LOW_THRESHOLD#
147  310102 = Exceeded upper humidity threshold of #HIGH_THRESHOLD#
148
149
150 [ PopupText ]
151  1003 = Normal utility power at #HOSTNAME# has been restored.
152  1006 = Shutdown of #HOSTNAME# has been cancelled.
153  1007 = UPS batteries at #HOSTNAME# are no longer discharged.
154  1016 = Shutdown process started.
155
156  2000 = #HOSTNAME# is running on battery power.
157  2001 = #HOSTNAME# has been shutdown.
158  2003 = Low battery power at #HOSTNAME#.
159
160  3000 = #HOSTNAME# has lost communications with the UPS.
161  3003 = UPS batteries at #HOSTNAME# are discharged.
162
163
164
165 [ FlexEventNames ]
166  1000 = PowerChute Started
167  1001 = PowerChute Stopped
168  1002 = Communication Established
169  1003 = Power Restored
170  1004 = UPS Self-Test Passed
171  1005 = Administrative Shutdown
172  1006 = Shutdown Cancelled
173  1007 = UPS Return From Low Battery
174  1009 = Battery No Longer Needs Replacing
175  1010 = Contact Normal
176  1013 = UPS Overload Condition Solved
177  1014 = UPS Run Time Calibration Initiated
178  1015 = UPS Run Time Calibration Completed
179  1016 = System Shutdown Starting
180  1017 = Return From Bypass
181  1018 = Smart Cell Signal Returned
182
183  1100 = Ambient Temp In Range
184  1101 = Humidity In Range
185
186  2000 = UPS On Battery
187  2001 = System Shutdown Complete
188  2002 = UPS Enabling SmartBoost
189  2003 = Low Battery Condition
190  2004 = Cancel Battery Calibration
191  2013 = UPS On Bypass: Maintenance
192
193
194  3000 = Unable To Communicate With UPS
195  3001 = UPS Output Overload
196  3002 = UPS Self-Test Failed
197  3003 = UPS Battery Is Discharged
198  3004 = Comm Lost While On Battery
199  3006 = Abnormal Contact Position
200  3010 = Check Smart Cell Signal
201  3013 = UPS On Bypass: Failure
202  3014 = Base Module Fan Failure
203  3015 = Base Module Power Supply Failure
204  3016 = UPS Battery Needs Replacing
205
206  3100 = Ambient Temp Out Of Range
207  3101 = Humidity Out Of Range
208
209
210 [ Email ]
211  Password = APC
212
213 [ LineFail ]
214  NotifyDelay = 5
215  NotifyInterval = 30
216  NotifyRepeat = Yes
217  ShutdownDelay = 300
218  Actions = LUS
219
220 [ AdminShutdown ]
221  ShutdownDelay = 900
222  NotifyRepeat = Yes
223
224 [ Network ]
225  UseTCP = YES
226
227 [ Security ]
228  RunCommandFilesAsRoot = NO
229  SendEmailAsRoot = NO
230
231 [ Help ]
232  WebBrowser = /usr/X11R6/bin/netscape
233  
234 [ Modem ]  
235  PortName = /dev/modem
236  ModemAllowedPortNames = /dev/modem,/dev/ttyS0,/dev/ttyS1
This page took 0.165713 seconds and 3 git commands to generate.