Commit | Line | Data |
---|---|---|
ec1d83db JR |
1 | [ Ups ] |
2 | SignallingType = smart | |
3 | PortName = /dev/ttyS0 | |
4 | AutoUpsRebootEnabled = Yes | |
5 | AllowedPortNames = /dev/ttyS0,/dev/ttyS1 | |
6 | CableType = Normal | |
7 | ||
8 | ||
9 | [ EventLogging ] | |
10 | EventLogEnabled = Yes | |
11 | EventLogName = /var/log/powerchute.log | |
12 | EventLogMaxSize = 50000 | |
13 | ||
14 | ||
15 | [ DataLogging ] | |
16 | DataLogEnabled = Yes | |
17 | DataLogName = /var/log/powerchute.dat | |
18 | DataLogMaxSize = 50000 | |
19 | DataLogInterval = 600 | |
20 | ||
21 | [ ErrorLogging ] | |
22 | ErrorLogEnabled = Yes | |
23 | ErrorLogName = /var/log/powerchute.err | |
24 | ErrorLogMaxSize = 50000 | |
25 | ||
26 | ||
27 | [ Messaging ] | |
28 | MessageDelay = 5 | |
29 | MessageInterval = 30 | |
30 | ||
31 | ||
32 | [ SelfTests ] | |
33 | EnableSelfTests = Yes | |
34 | SelfTestDay = MONDAY | |
35 | SelfTestSchedule = At turn on | |
36 | SelfTestTime = 12:00 PM | |
37 | ||
38 | ||
39 | [ Shutdown ] | |
40 | ShutdownDelay = 30 | |
41 | AdminShutdownDelay = 900 | |
42 | DailyShutdownEnabled = No | |
43 | DailyShutdownTime = 6:00 PM | |
44 | DailyWakeupTime = 7:00 AM | |
45 | WeeklyShutdownEnabled = No | |
46 | WeeklyShutdownDay = Friday | |
47 | WeeklyShutdownTime = 6:00 PM | |
48 | WeeklyWakeUpDay = Monday | |
49 | WeeklyWakeUpTime = 7:00 AM | |
50 | ||
51 | [ Server ] | |
52 | HostName = | |
53 | ||
54 | [ UserInterface ] | |
55 | TemperatureUnits = Celsius | |
56 | SoundEffects = No | |
57 | ||
58 | [ BatteryCalibration ] | |
59 | Enabled = No | |
60 | BatteryCalibrationDay = Monday | |
61 | BatteryCalibrationTime = 07:00 AM | |
62 | ||
63 | [ Devices ] | |
64 | MeasureUps = NO | |
65 | ||
66 | [ EventText ] | |
67 | 100000 = *** PowerChute PLUS Version 4.5.2 (glibc) Started *** | |
68 | 100100 = *** PowerChute PLUS Stopped *** | |
69 | 100200 = Communication established | |
70 | 100300 = Normal power restored: UPS on line | |
71 | 100400 = UPS self-test passed | |
72 | 100401 = Scheduled UPS self-test passed | |
73 | 100402 = User initiated UPS self-test passed | |
74 | 100403 = Self-test at UPS passed | |
75 | 100500 = Administrative shutdown started | |
76 | 100501 = Administrative shutdown: User initiated | |
77 | 100502 = Administrative shutdown: Weekly shutdown | |
78 | 100503 = Administrative shutdown: Daily shutdown | |
79 | 100600 = Shutdown cancelled | |
80 | 100601 = User initiated shutdown cancelled | |
81 | 100602 = Weekly administrative shutdown cancelled | |
82 | 100603 = Daily administrative shutdown cancelled | |
83 | 100700 = UPS returned from low battery condition | |
84 | 100701 = UPS returned from low battery condition: #BATTERY_CAPACITY#% | |
85 | 100900 = UPS batteries no longer need replacing | |
86 | 101000 = Contact #CONTACT_NUMBER# normal (#NORMAL_POSITION#): #USER_COMMENT# | |
87 | 101300 = UPS overload condition solved | |
88 | 101400 = UPS run time calibration initiated | |
89 | 101500 = UPS run time calibration completed | |
90 | 101600 = Shutdown started | |
91 | 101601 = User initiated shutdown started | |
92 | 101602 = Weekly administrative shutdown started | |
93 | 101603 = Daily administrative shutdown started | |
94 | 101700 = UPS returned from bypass | |
95 | 101800 = Smart Cell Signal Restored | |
96 | 110000 = Ambient temperature back within thresholds | |
97 | 110100 = Ambient humidity back within thresholds | |
98 | ||
99 | ||
100 | 200000 = UPS on battery | |
101 | 200001 = UPS on battery: High input line voltage #MAX_VOLTAGE# V | |
102 | 200002 = UPS on battery: Brownout #MIN_VOLTAGE# V | |
103 | 200003 = UPS on battery: Blackout #MIN_VOLTAGE# V | |
104 | 200004 = UPS on battery: Small momentary sag #MIN_VOLTAGE# V | |
105 | 200006 = UPS on battery: Deep momentary sag #MIN_VOLTAGE# V | |
106 | 200005 = UPS on battery: Small momentary spike #MAX_VOLTAGE# V | |
107 | 200007 = UPS on battery: Large momentary spike #MAX_VOLTAGE# V | |
108 | 200008 = UPS on battery: Simulated power failure | |
109 | 200100 = System shutdown | |
110 | 200200 = UPS enabling SmartBoost | |
111 | 200300 = Low battery condition | |
112 | 200301 = Low battery condition: #BATTERY_CAPACITY#% | |
113 | 200400 = UPS run time calibration cancelled | |
114 | 200401 = UPS run time calibration cancelled by user | |
115 | 200402 = UPS run time calibration cancelled by power failure | |
116 | 200403 = UPS unable to perform run time calibration: Capacity < 100% | |
117 | 201301 = UPS on bypass: user set via software or panel | |
118 | 201302 = GSUB_CHANGE13_HERE | |
119 | ||
120 | ||
121 | 300000 = Unable to communicate with UPS | |
122 | 300100 = UPS output overload | |
123 | 300200 = UPS self-test failed | |
124 | 300201 = Scheduled UPS self-test failed: Bad battery | |
125 | 300202 = Scheduled UPS self-test failed: Invalid test | |
126 | 300203 = User initiated self-test failed: Bad battery | |
127 | 300204 = User initiated self-test failed: Invalid test | |
128 | 300205 = Self-test at UPS failed: Bad battery | |
129 | 300206 = Self-test at UPS failed: Invalid test | |
130 | 300300 = UPS battery is discharged | |
131 | 300301 = UPS battery is discharged: #BATTERY_CAPACITY#% | |
132 | 300400 = Communication lost while on battery | |
133 | 300600 = Contact #CONTACT_NUMBER# fault (#CONTACT_POSITION#): #USER_COMMENT# | |
134 | 301000 = Check installation of Smart Cell signal cable | |
135 | 301300 = UPS on bypass internal temp over limit | |
136 | 301301 = UPS on bypass battery charger failure | |
137 | 301302 = UPS on bypass: severe DC imbalance overload | |
138 | 301303 = UPS on bypass: output voltage outside limits | |
139 | 301304 = UPS on bypass: top module fan needs repair | |
140 | 301400 = Base module fan needs repair | |
141 | 301500 = Base module bypass power supply needs repair | |
142 | 301600 = UPS battery needs replacing | |
143 | ||
144 | 310001 = Below lower ambient temperature threshold of #LOW_THRESHOLD# | |
145 | 310002 = Exceeded upper ambient temperature threshold of #HIGH_THRESHOLD# | |
146 | 310101 = Below humidity threshold of #LOW_THRESHOLD# | |
147 | 310102 = Exceeded upper humidity threshold of #HIGH_THRESHOLD# | |
148 | ||
149 | ||
150 | [ PopupText ] | |
151 | 1003 = Normal utility power at #HOSTNAME# has been restored. | |
152 | 1006 = Shutdown of #HOSTNAME# has been cancelled. | |
153 | 1007 = UPS batteries at #HOSTNAME# are no longer discharged. | |
154 | 1016 = Shutdown process started. | |
155 | ||
156 | 2000 = #HOSTNAME# is running on battery power. | |
157 | 2001 = #HOSTNAME# has been shutdown. | |
158 | 2003 = Low battery power at #HOSTNAME#. | |
159 | ||
160 | 3000 = #HOSTNAME# has lost communications with the UPS. | |
161 | 3003 = UPS batteries at #HOSTNAME# are discharged. | |
162 | ||
163 | ||
164 | ||
165 | [ FlexEventNames ] | |
166 | 1000 = PowerChute Started | |
167 | 1001 = PowerChute Stopped | |
168 | 1002 = Communication Established | |
169 | 1003 = Power Restored | |
170 | 1004 = UPS Self-Test Passed | |
171 | 1005 = Administrative Shutdown | |
172 | 1006 = Shutdown Cancelled | |
173 | 1007 = UPS Return From Low Battery | |
174 | 1009 = Battery No Longer Needs Replacing | |
175 | 1010 = Contact Normal | |
176 | 1013 = UPS Overload Condition Solved | |
177 | 1014 = UPS Run Time Calibration Initiated | |
178 | 1015 = UPS Run Time Calibration Completed | |
179 | 1016 = System Shutdown Starting | |
180 | 1017 = Return From Bypass | |
181 | 1018 = Smart Cell Signal Returned | |
182 | ||
183 | 1100 = Ambient Temp In Range | |
184 | 1101 = Humidity In Range | |
185 | ||
186 | 2000 = UPS On Battery | |
187 | 2001 = System Shutdown Complete | |
188 | 2002 = UPS Enabling SmartBoost | |
189 | 2003 = Low Battery Condition | |
190 | 2004 = Cancel Battery Calibration | |
191 | 2013 = UPS On Bypass: Maintenance | |
192 | ||
193 | ||
194 | 3000 = Unable To Communicate With UPS | |
195 | 3001 = UPS Output Overload | |
196 | 3002 = UPS Self-Test Failed | |
197 | 3003 = UPS Battery Is Discharged | |
198 | 3004 = Comm Lost While On Battery | |
199 | 3006 = Abnormal Contact Position | |
200 | 3010 = Check Smart Cell Signal | |
201 | 3013 = UPS On Bypass: Failure | |
202 | 3014 = Base Module Fan Failure | |
203 | 3015 = Base Module Power Supply Failure | |
204 | 3016 = UPS Battery Needs Replacing | |
205 | ||
206 | 3100 = Ambient Temp Out Of Range | |
207 | 3101 = Humidity Out Of Range | |
208 | ||
209 | ||
210 | [ Email ] | |
211 | Password = APC | |
212 | ||
213 | [ LineFail ] | |
214 | NotifyDelay = 5 | |
215 | NotifyInterval = 30 | |
216 | NotifyRepeat = Yes | |
217 | ShutdownDelay = 300 | |
218 | Actions = LUS | |
219 | ||
220 | [ AdminShutdown ] | |
221 | ShutdownDelay = 900 | |
222 | NotifyRepeat = Yes | |
223 | ||
224 | [ Network ] | |
225 | UseTCP = YES | |
226 | ||
227 | [ Security ] | |
228 | RunCommandFilesAsRoot = NO | |
229 | SendEmailAsRoot = NO | |
230 | ||
231 | [ Help ] | |
232 | WebBrowser = /usr/X11R6/bin/netscape | |
233 | ||
234 | [ Modem ] | |
235 | PortName = /dev/modem | |
236 | ModemAllowedPortNames = /dev/modem,/dev/ttyS0,/dev/ttyS1 |