2 # inittab This file describes how the INIT process should set up
3 # the system in a certain run-level.
5 # Author: Miquel van Smoorenburg, <miquels@drinkel.nl.mugnet.org>
6 # Modified for RHS Linux by Marc Ewing and Donnie Barnes
7 # Modified for PLD Linux by Wojtek ¦lusarczyk
9 # Default runlevel. The runlevels used by PLD are:
10 # 0 - halt (Do NOT set initdefault to this)
11 # 1 - Single user mode
12 # 2 - Multiuser, without NFS (The same as 3, if you do not have networking)
13 # 3 - Full multiuser mode
16 # 6 - reboot (Do NOT set initdefault to this)
20 # System initialization.
21 si::sysinit:/etc/rc.d/rc.sysinit
23 l0:0:wait:/etc/rc.d/rc 0
24 l1:1:wait:/etc/rc.d/rc 1
25 l2:2:wait:/etc/rc.d/rc 2
26 l3:3:wait:/etc/rc.d/rc 3
27 l4:4:wait:/etc/rc.d/rc 4
28 l5:5:wait:/etc/rc.d/rc 5
29 l6:6:wait:/etc/rc.d/rc 6
31 # Things to run in every runlevel.
34 # Trap CTRL-ALT-DELETE
35 #ca::ctrlaltdel:/sbin/shutdown -t3 -r now
37 # When our UPS tells us power has failed, assume we have a few minutes
38 # of power left. Schedule a shutdown for 2 minutes from now.
39 # This does, of course, assume you have powerd installed and your
40 # UPS connected and working correctly.
41 pf::powerfail:/sbin/shutdown -f -h +2 "Power Failure; System Shutting Down"
43 # If power was restored before the shutdown kicked in, cancel it.
44 pr:12345:powerokwait:/sbin/shutdown -c "Power Restored; Shutdown Cancelled"
47 # Run gettys in standard runlevels
48 1:12345:respawn:/sbin/mingetty --noclear tty1
49 2:2345:respawn:/sbin/mingetty tty2
50 3:2345:respawn:/sbin/mingetty tty3
51 4:2345:respawn:/sbin/mingetty tty4
52 5:2345:respawn:/sbin/mingetty tty5
53 6:2345:respawn:/sbin/mingetty tty6
55 # Run xdm in runlevel 5
56 x:5:respawn:/usr/bin/X11/xdm -nodaemon